FAQ ID Description
FA22665Is it possible to read the IP address of connected device at runtime in Vijeo Designer.
Yes, it is possible to read the IP address of connected devices via scripting during runtime. This feature has been implemented in Vijeo Designer...
FA61How to get Vijeo Designer and Vijeo Designer Runtime version information on Magelis XBT G/GT terminal during runtime.
System configuration menu item can be used to display VJD & VJD Runtime version information during runtime of the Magelis XBT G/GT terminal during...
FA22664Is it possible to write a new IP address of connected device at runtime in Vijeo Designer.
Yes, it is possible to write a new IP address of connected devices via scripting during runtime. This feature has been implemented in Vijeo Designer...
FA12037What are the techniques to optimize the memory usage of Vijeo Designer project.
The following are helpful guidelines to optimize the memory usage of Vijeo Designer project. 1. Delete unused variables2. Use indirect addresses and...
FA12038What is the naming convention for Vijeo Designer application.
The following characters are valid characters that can be used for naming parts, devices, object, variables and passwords in Vijeo-Designer. a) Alphabet...
FA12171What is the Part Reference of Resolver card for Altivar 71 Drive.
The Part Reference of Resolver card is VW3A3408.Note: Resolver card VW3A3408 is only compatible with ATV71...383 Drives. This card is not compatible...
FA12149How Altivar 61 Drive can be auto started after Power ON.
In order to avail the auto start facility after Power ON, following Parameters have to be programmed as below: In [1.5 INPUTS/OUTPUTS CFG](I-O) Menu. 1....
FA12154When does the cooling fan of Altivar 71 Drive start.
In Altivar 71 drive from frame Size 2 to 5b the fan starts on a temperature Threshold (THD) = 70%.And from frame Size 6 to 15 the drive cooling fan...
FA12141What is the heat dissipation of the Altivar 61 Drive when it is in Ready state.
The heat dissipation value of the Altivar 61 Drives when in Ready State (RDY - Drive is powered up but motor is not running) depends on the size of...
FA12145Is the remote keypad option available for Altivar 21 Drive.
Yes, the remote keypad option is available for the Altivar 21 Drive. The reference for the same is VW3A21101. It can be installed remotely up to a...